IEC60068-2-75 Calibration Device for Calibrating Ik01-Ik07 Spring Hammer
-
Price:
Negotiable
- minimum:
- Total supply:
-
Delivery term:
The date of payment from buyers deliver within days
-
seat:
Jiangxi
-
Validity to:
Long-term effective
-
Last update:
2017-09-01 03:04
-
Browse the number:
238
+
Pego Group (HK) Co., Limited
- Contactaixin:
Ms. Penny(Mr.)
- Email: telephone: phone:
-
Arrea:
Jiangxi
Address:No. 233, Yangshan Road, Yuanzhou District, Yichun, Jiangxi, China 336000
- Website:
+
IEC60068-2-75 Spring Hammer Calibrator Device
Introduction:
Spring hammer calibrator device is specially for lab to calibrate the spring hammer, it is designed according to IEC60065-2-75-1997, it is mainly apply to third part lab, the National immigration department and appliance-related research institutes.
Parameter:
Relative Products:
Spring impact hammer
Introduction:
IK ratings are defined as IKXX, XX is a number from 00 to 10 which indicates the degrees of protection provided by enclosures against external mechanical impacts. The different IK rating relate to the ability of an enclosure to resist impact energy levels measured in joules (J). It is designed according to IEC60068-2-75 Ehb, and can applicate to IEC60598, IEC60068-2-75 and etc.
Degrees of protection against external mechanical impacts
IK07-IK10 Pendulum Impact Hammer
Introduction:
This device is designed according to O-1997 and IEC62262, and can meet the test requirements of IEC60598, EN50102, GB2423.55-2006, GB20138-2006 and etc. It is apply to sheet metal for mechanical impact testing. The device can be adjusted back and forward, left and right, and the angle also can be adjusted.
Specification
Angle: 0~900 adjustable
Length of swing rod: 1000mm
Impact hammers: 1.7kg, 5kg, 5kg, 10kg steel hammers with swing rods
Impact height: 200~1200mm adjustable
Impact energy: 2J, 5J, 10J, 20J
Note:
The standard configuration includes 0.5kg, 1.7kg and 5kg hammers for IK 07 to IK10 testing, 10KG hammer for 50J test is a optional device.
Degrees of protection against external mechanical impacts
Introduction:
Spring hammer calibrator device is specially for lab to calibrate the spring hammer, it is designed according to IEC60065-2-75-1997, it is mainly apply to third part lab, the National immigration department and appliance-related research institutes.
Parameter:
Accuracy | 0.01J |
Repeatability | ±0.01J |
Impact energy range | 0J ~2J |
Guide groove diameter | 51mm |
Energy loss | <0.002J |
Trigger travel | >30mm |
Number of calibration weights | 1 |
Relative Products:
Spring impact hammer
Introduction:
IK ratings are defined as IKXX, XX is a number from 00 to 10 which indicates the degrees of protection provided by enclosures against external mechanical impacts. The different IK rating relate to the ability of an enclosure to resist impact energy levels measured in joules (J). It is designed according to IEC60068-2-75 Ehb, and can applicate to IEC60598, IEC60068-2-75 and etc.
Degrees of protection against external mechanical impacts
IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J |
Model | Impact Energy |
IK01 (single) | 0.14±0.01J |
IK02 (single) | 0.20±0.02J |
IK03 (single) | 0.35±0.03J |
IK04 (single) | 0.50±0.04J |
IK05 (single) | 0.70±0.05J |
IK06 (single) | 1.00±0.05J |
Ik07 (single) | 2.00±0.10J |
IK01-IK06 (universal) | 0.14J~1.00J |
IK07-IK10 Pendulum Impact Hammer
Introduction:
This device is designed according to O-1997 and IEC62262, and can meet the test requirements of IEC60598, EN50102, GB2423.55-2006, GB20138-2006 and etc. It is apply to sheet metal for mechanical impact testing. The device can be adjusted back and forward, left and right, and the angle also can be adjusted.
Specification
Angle: 0~900 adjustable
Length of swing rod: 1000mm
Impact hammers: 1.7kg, 5kg, 5kg, 10kg steel hammers with swing rods
Impact height: 200~1200mm adjustable
Impact energy: 2J, 5J, 10J, 20J
Note:
The standard configuration includes 0.5kg, 1.7kg and 5kg hammers for IK 07 to IK10 testing, 10KG hammer for 50J test is a optional device.
Characteristics 0f Striking Elements | ||||||
Energy/J | ≤1 ±10% |
2 ±5% |
5 ±5% |
10 ±5% |
20 ±5% |
50 ±5% |
Equivalent mass±2%kg | 0.25(0.2) | 0.5 | 1.7 | 5 | 5 | 10 |
Material | Nylon | steel | ||||
R/mm | 10 | 25 | 25 | 50 | 50 | 50 |
D/mm | 18.5(20) | 35 | 60 | 80 | 100 | 125 |
f/mm | 6.2(10) | 7 | 10 | 20 | 20 | 25 |
r/mm | - | - | 6 | - | 10 | 17 |
l/mm | Depends |
Fall Height | |||||||||||||||
Energy/J | 0.14 | 0.2 | (0.3) | 0.35 | (0.4) | 0.5 | 0.7 | 1 | 2 | 5 | 10 | 20 | 50 | ||
Equivalent mass/kg | 0.25 | (0.2) | 0.25 | (0.2) | 0.25 | (0.2) | (0.2) | 0.25 | 0.25 | 0 .25 | 0.5 | 1.7 | 5 | 5 | 10 |
Fall height±1%mm | 56 | (100) | 80 | (150) | 140 | (200) | (250) | 200 | 280 | 400 | 400 | 300 | 200 | 400 | 500 |
Degrees of protection against external mechanical impacts
IK01 | IK02 | IK03 | IK04 | IK05 | IK06 | IK07 | IK08 | IK09 | IK10 |
0.14J | 0.2J | 0.35J | 0.5J | 0.7J | 1J | 2J | 5J | 10J | 20J |